CVM k2-ITF-405, Analyzer
Code: M54400.
- Protocol: Modbus/RTU
- Communications: RS-485
- Class in power: 0.5
INFORMATION
DESCRIPTION
Three-phase power analyzer (balanced and unbalanced networks), assembly on panels or DIN rails, with a graphical display, with 4-quadrant measurement.
Other features include:
- Class 0.2 or 0.5 power and energy
- Measurement of power quality events (guaranteeing the power supply of the unit by means of a UPS system, battery, etc.)
- Current measurement …/5 or …/1 A
- Measurement of the neutral current with a transformer
- Rating of consumed and generated energy (up to 9 tariffs)
- RS-485 Modbus/RTU communication
- Possibility of expansion (up to 3 modules)
- Backlit VGA graphic screen
- Instantly shows electrical parameters, maximum and minimum values with date and time
- Consumed and generated energy meter up to 100 GW·h
- Universal power supply as standard
- With ITF technology: galvanic insulation protection
APPLICATIONS
- Control application for general distribution switchboards and low-, medium- and high-voltage connection points
- Alarm station, featuring voltage-free digital inputs
- Submetering station: impulse meter for other services (gas, water, steam etc.) via the digital inputs
- Measurement transducer: possibility of associating instantaneous parameters with one of the available analogue outputs (0 to 20 mA / 4 to 20 mA)
- Unit for recording the instantaneous, maximum and minimum parameters, with date and time, via the memory expansion card
- Power quality analyzer: Harmonic decomposition, up to the 50th order harmonic, asymmetries, flicker, unbalances, overvoltages, gaps, interruptions, etc.
- SPECIFICATIONS
- AC POWER SUPPLY
- Installation category
- CAT III 300/520 Vac (IEC 61010)
- Consumption
- <30 VA
- Frequency
- 50…60Hz
- Nominal voltage
- 85…265 Vc.a. (-15…+10%)
- DC POWER SUPPLY
- Consumption
- <25 W
- Nominal voltage
- 100…300 Vdc
- MECHANICAL CHARACTERISTICS
- Size (mm) width x height x depth
- 144 x 144 x 116 (mm)
- Envelope
- Self-extinguishing V0 plastic
- Cable gauge at power supply terminals
- 1 mm2(mín)
- Cable gauge at current terminals
- 2,5 mm2
- Cable gauge at voltage terminals
- 1 mm2
- Weight (kg)
- 0,81
- ENVIRONMENTAL CHARACTERISTICS
- Protection class
- IP 51 (Front), IP 20 (rear)
- Relative humidity (without condensation)
- 5…95%
- Storage temperature
- -20…+65 ºC
- Working temperature
- -10…+50 ºC
- STANDARDS
- Certifications
- CE, UL, VDE
- Electrical safety, Maximum height (m)
- 2000
- Electrical safety, Installation category
- CAT III 300V / 520V, IEC 61010
- Standards
- IEC 664, VDE 0110, UL 94, IEC 801, IEC 348, IEC 571-1, EN 61000-6-3, EN 61000-6-1, EN 61010-1, EN 61000-4-11, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 55011, IEC 62053-22
- CURRENT MEASUREMENT CIRCUIT
- Nominal current (In)
- In/5A, In/1A
- Primary current measurement
- Programmable < 30000 A
- Phase current measuring range
- 1…120% In (In = 5 A)
- Permanent overload
- 2 In
- Maximum input current consumption
- <0,45 VA (…/5 , …/1)
- Maximum pulse current
- 100 A
- Minimum current measurement
- 40 mA
- VOLTAGE MEASUREMENT CIRCUIT
- Installation category
- CAT III 300/520 V (EN-61010)
- Frequency measuring range
- 45…65 Hz
- Voltage measuring range
- 5 …120% Un
- Nominal voltage
- 300V Ph-N, 520V Ph-Ph
- Maximum input voltage consumption
- <0,6 VA
- Minimum measurement voltage (Vstart)
- 10 V~
- COMMUNICATIONS
- Fieldbus
- RS-485 / Ethernet RJ-45
- Stop bits (ModBus)
- 1 – 2
- Parity
- non-pair-impar
- Protocol
- ModBus/RTU, ModBus/TCP
- Speed
- 9600 – 19200 – 38400 – 57600 / Ethernet: 10baseT / 100base /Tx compatible
- Peripheral number
- 1…255
- ELECTRICAL SAFETY
- Insulation
- Double-insulated electric shock protection class II (IEC 61010-1)
- DIGITAL INPUTS
- Consumption (per input)
- <0,5 W
- Minimum signal width
- 40 ms
- Operating voltage
- 24 Vdc ± 20 %
- ANALOGUE OUTPUTS
- Current mode, nominal range
- 0-20 mA/4-20 mA
- Current mode: maximum load resistance
- 300 Ω
- DAC resolution
- 4000 points
- Response time
- < 2 s
- DIGITAL TRANSISTOR OUTPUTS
- Type
- Optocoupler
- Maximum current
- 100 mA
- Maximum resistance RON
- 25 Ω
- Maximum voltage
- 150 Vdc / 250 V~
- MEASUREMENT ACCURACY
- Power factor measurement
- 0,5…1
- Phase voltage measurement
- ± 0,5% ± 1 (20 … 120% Un)