Description
computer Max P&P 12, Power factor regulator
Code: R10872.
- Alarm relay: Yes
- Measurement Range (V): 400
- Power supply (Vac): 400 Vac
- Nr steps: 12
- Input current: … / 5A
- Switching unit: Contactor
INFORMATION
DESCRIPTION
The state-of-the-art computer Max plug & play series of regulators has been designed to enable easy, effective regulation. In common with the entire range of computer regulators, it is based on Circutor’s FCP system (Fast Computerized Program), which provides the regulator with unique features in the market Other features include:
- A Plug & Play system that enables fully automatic programming of the C/K parameter and selection of the phase on which the current transformer is installed.
- Views by display: cos φ, voltage, current, THDI and it records maximum voltage and current levels.
- Includes the “phase selection” function, which allows the user to select the phase on which the current transformer is installed.
- Allows the user to view the behaviour of cos φ, I and THDI in the event of manual connection and disconnection of capacitors.
- Indication of the following alarms by display or relay:lack of compensation, overcompensation, overvoltage, overcurrent, disconnected transformer, current below limit.
APPLICATIONS
Computer Max plug & play is the perfect regulator for the compensation of balanced installations, in which ease of programming, robustness and accuracy are essential requirements. Its straightforward, intuitive programming system makes it very easy to install and maintain by the user.
SPECIFICATIONS
AC POWER SUPPLY
Installation category
CAT III 300 V
Consumption
110 V: 7 … 10 VA / 230 V: 7,4 … 9,9 VA / 400 V: 5 … 8,8 VA / 480 V: 8,7 … 10,7 VA
Frequency
45 … 65 Hz
Nominal voltage
480, 400, 230 ó 110 V ~ (+15, -10 % según modelo)
MECHANICAL CHARACTERISTICS
Size (mm) width x height x depth
144 x 144 x 62 (mm)
Envelope
Plastic V0 self-extinguishing
Fastening
Panel
Weight (kg)
0,514
ENVIRONMENTAL CHARACTERISTICS
Protection class
IP 30 / Front: IP 40
Relative humidity (without condensation)
5 … 95 %
Storage temperature
-20 … +70 ºC
Working temperature
-20 … +60 ºC
STANDARDS
Certifications
UL
Electrical safety, Maximum height (m)
2000
Standards
IEC 61010, IEC 61000-3-2, IEC 61000-3-3, IEC 50081-2, IEC 50082-1, IEC 50082-2, IEC 61000-4-2, IEC 61000-4-4, IEC 61000-4-8, IEC 61000-4-5, IEC 61000-4-11 , UL 94
CURRENT MEASUREMENT CIRCUIT
Nominal current (In)
… / 5 A
Phase current measuring range
0.05 … 5A
Permanent overload
+ 20%
Connection
Preferably connect to phase L1
ELECTRICAL SAFETY
Insulation
Double-insulated electric shock protection class II (IEC 61010-1)
USER INTERFACE
LED
2 LED
Resolution of the display
3 digits, 7 segments + 20 icons
Keyboard
3 keys
OTHER DIGITAL RELAY OUTPUTS
Maximum current
6 A (12 A bornes de conexión)
DIGITAL RELAY OUTPUTS
Quantity
12
Maximum open contact voltage
250 V ~
MEASUREMENT ACCURACY
Phase angle φ
2 % ± 1 dígito
Phase current measurement
1%
Phase voltage measurement
1%
Reviews
There are no reviews yet.