Description
CVM-NET4+-ITF-MC-RS485-C4, Power analyzer
Code: M55782.
- Protocol: Modbus/RTU
- Communications: RS-485
- Transistor output: 4
- Harmonics: 15
- Input current: …/250 mA
- Mounting: DIN rail
INFORMATION
DESCRIPTION
CVM-NET4+ is a multi-channel power analyzer designed to measure balanced or unbalanced three-phase networks and to measure single-phase networks. Its versatile configuration options enable you to take measurements in single-phase systems, three-phase systems or a combination of both. It has a single three-phase voltage input combined with 12 single-phase channels to measure the current from the MC efficient current transformers.
Its main features include:
- Assembly on DIN rail
- Compact size (6 DIN rail modules)
- Measurement of up to 12 single-phase channels or combined single-phase and three-phase current channels.
- Current measurement using efficient MC series transformers (…/250 mA)
- RS-485 Communications (Modbus/RTU)
- 4 programmable digital outputs for alarms or impulses
- Compatible with PowerStudio /PowerStudio Scada / PowerStudio Scada Deluxe
APPLICATIONS
- Measurement of electrical parameters in multi-channel installations, such as data processing centres and switchboards of single-phase loads.
- Simultaneous measurement at 4 different points in three-phase installations
- Its compact size is perfect for assembly on electric panels.
- SPECIFICATIONS
- AC POWER SUPPLY
- Installation category
- CAT III 300 V
- Consumption
- 6 VA
- Frequency
- 50…60Hz
- Nominal voltage
- 85…265 Vc.a.
- DC POWER SUPPLY
- Installation category
- CAT III 300 V
- Consumption
- 6 W
- Nominal voltage
- 95…300 Vdc
- MECHANICAL CHARACTERISTICS
- Size (mm) width x height x depth
- 105 x 90 x 70 (mm)
- Envelope
- Self-extinguishing V0 plastic
- Fastening
- DIN rail 46227 (EN 50022)
- Weight (kg)
- 0,234
- ENVIRONMENTAL CHARACTERISTICS
- Protection class
- IP 51 (Front), IP 31 (unmounted)
- Relative humidity (without condensation)
- 5…95%
- Working temperature
- -10…+50 ºC
- STANDARDS
- Certifications
- UL, VDE
- Electrical safety, Maximum height (m)
- 2000
- Electrical safety, Installation category
- CAT III 300V / 520V, IEC 61010
- Standards
- IEC 664, VDE 0110, UL 94, IEC 801, IEC 348, IEC 571-1, EN 61000-6-3,EN 61000-6-1, EN 61010-1, EN 61000-4-11, EN 61000-4-3, EN 61000-4-3,EN 61000-4-4, EN 61000-4-5, EN 55011
- CURRENT MEASUREMENT CIRCUIT
- Installation category
- CAT III 300 V
- Nominal current (In)
- …/250 mA
- Phase current measuring range
- 0…250 mA
- Permanent overload
- 3 In
- Maximum input current consumption
- 0,18 VA x 4 channels
- Maximum pulse current
- In x 1.3
- Minimum current measurement
- 3 mA
- VOLTAGE MEASUREMENT CIRCUIT
- Installation category
- CAT III 300 V
- Input impedance
- 4 MΩ
- Frequency measuring range
- 45 … 65 Hz
- Nominal voltage
- 300V Ph-N, 520V Ph-Ph
- Maximum input voltage consumption
- 0,7 VA
- Minimum measurement voltage (Vstart)
- 5 V~
- COMMUNICATIONS
- Fieldbus
- RS-485
- Stop bits (ModBus)
- 1
- Parity
- non
- Protocol
- ModBus RTU
- Speed
- 9600 – 19200 – 38400 – 57600
- ELECTRICAL SAFETY
- Insulation
- Double-insulated electric shock protection class II (IEC 61010-1)
- DIGITAL TRANSISTOR OUTPUTS
- Pulse width
- 100 ms
- Quantity
- 4
- Type
- NPN
- Maximum frequency
- 5 imp / s
- Maximum current
- 50 mA
- Maximum voltage
- 24 Vdc
- MEASUREMENT ACCURACY
- Current measurement sensors
- External transformers
- Voltage measurement sensors
- Direct voltage
- Phase voltage measurement
- 0,50%