MYeBOX-1500-3 FLEX-R80

Compare
Category:

Description

MYeBOX-1500-3 FLEX-R80, Portable power analyzer with recording of quality events and transients

Code: M8405D0000A00

  • Nr Sensors: 3 FLEX-R80
  • Communications: Wi-Fi | 3G
  • Transistor output: 2
  • Digital inputs: 2
  • of voltage measurement inputs: 5
  • Measuring current Channels: 5
  • Class: Class A

 

INFORMATION

DESCRIPTION

MYeBOX® is a range of portable analysers that can be configured from an app and/or a website to analyse and record electrical parameters, measure and record waveform transients and network quality parameters, as per the EN 50160 standard. The information is accessible remotely from the app and/or website. MYeBOX® measures and records electrical parameters in single-phase, two-phase or three-phase installations (with and without a neutral).
The app/website is connected to the device to display the measured data in real time, fully configure the device, start or stop the data recording, send the recorded data to the MYeBOX® Cloud platform, and even access the data from the memory to view it graphically or in table form. The remote connectivity lets you analyse the measured data from anywhere. The recorded data can also be sent to a data repository for further analysis in PowerVision Plus. The device can be configured locally using the capacitive keyboard and the on-screen menu options.

MYeBOX® 150 and MYeBOX® 1500 have the following features and functions:

  • 4 voltage measurement inputs (U1U2U3Un)
  • 4 current measurement inputs (I1I2I3In)
  • Measurement of the main electrical parameters
  • Measurement of network quality parameters
  • True RMS measurement (TRMS)
  • Measurement of consumption and generation (4Q)
  • Voltage quality event log, according to EN 61000-4-30
  • Transients log
  • Recording of the wave shape associated with the quality events and transients
  • Measurement according to EN 61000-4-30
  • Power supply is independent of the measurement
  • Recording of the wave shape for each recording period
  • LCD Screen
  • Capacitive keypad
  • Micro-USB port to download data
  • Automatic detection of clamps
  • Identification of phases with colours
  • Compatible with clamps with EEPROM
  • Recording of system events (EVA)
  • NTP synchronisation
  • Sending of alarms via e-mail
  • Wi-Fi communications (access point/terminal)

 

The MYeBOX® 1500 model also has:

  • 1 voltage measurement input Uref
  • 1 leakage current measurement input
  • 2 transistor inputs to centralise impulses / tariff / state
  • 2 transistor outputs for alarms
  • 3G/4G communications

APPLICATIONS

MYeBOX can be used to:

  • Prepare complete studies of an electrical installation.
  • Analyse consumption, load curves, disturbances in the installation’s voltage, display wave shapes, harmonics study or flicker measurement, among other options.
  • Perform audits and analyses remotely.
  • SPECIFICATIONS
  • AUXILIARY BATTERY POWER SUPPLY
  • Autonomy
  • 2 h (without 3G), 50 min (with 3G)
  • Battery type
  • Litio (3,7 Vc.c.)
  • Capacity
  • 3700 mAh
  • Load temperature
  • 0 … 40 °C
  • Load time
  • 6 h
  • AC POWER SUPPLY
  • Installation category
  • CAT II 300 V
  • Consumption
  • 22…28 VA
  • Frequency
  • 47…63 Hz
  • Nominal voltage
  • 100…240 Vc.a.(Adaptador de alimentación de c.a.)
  • POWERED BY CHARGER, ADAPTER
  • Output voltage
  • 9 Vc.c.
  • Maximum power
  • 20 W
  • SPECIFIC TECHNICAL CHARACTERISTICS OF CURRENT SENSORS
  • Linearity
  • 2 % (10…200 % In)
  • Measurement range
  • 100/1000/10000 A
  • STANDARDS
  • Certifications
  • UL, CAN/CSA-C22.2 No. 61010-1, 3rd Edition, 2012-5, CE
  • Electrical safety, Maximum height (m)
  • 2000
  • Standards
  • Recycling European Directive 2002/96/EC, EN 61326-1, UL 61010-1, 3rd Edition, 2012-05-11, IEC 61010-1, 3rd Edition
  • CURRENT MEASUREMENT CIRCUIT
  • Installation category
  • CAT III 600 V
  • Nominal current (In)
  • Depending on the clamp
  • Phase current measurement
  • Transformadores con salida 0,250 A ó 0,333 V
  • Phase current measuring range
  • 1…200 % In
  • Maximum input current consumption
  • 0,0004 VA
  • Maximum pulse current
  • 3 x In A
  • Minimum current measurement
  • Depending on the clamp
  • VOLTAGE MEASUREMENT CIRCUIT
  • Installation category
  • CAT III 600 V
  • Consumption
  • 0,15 VA
  • Sampling frequency
  • 45…65 Hz
  • Input impedance
  • 2,4 MΩ
  • Voltage measuring range
  • 10…600 Vac
  • Minimum measurement voltage (Vstart)
  • 10 V ac
  • COMMUNICATIONS
  • Band
  • 2,4 GHz.
  • Networks
  • UMTS/HSPA: 850/900/1900/2100 MHz. # GSM /GPRS /EDGE: 850/900/1800/1900 MHz.
  • Maximum output power
  • UTMS/3G (Potencia Clase 3): 24dBM, GSM850/900 (Potencia Clase 4): 33dBM, GSM1800/1900 (Potencia Clase 1): 30 dBM.
  • Connection mechanism
  • Wi-Fi
  • ELECTRICAL SAFETY
  • Insulation
  • Double-insulated electric shock protection class II (IEC 61010-1)
  • DIGITAL INPUTS
  • Input/output insulation
  • 2,7 kV
  • Quantity
  • 2
  • Type
  • Potential-free contact
  • Maximum short-circuit current
  • 5 mA
  • Maximum open circuit voltage
  • 4…9 Vdc
  • MEMORY
  • Format
  • FAT 32
  • Write time
  • 1s, 1m, 5m, 15m, 1h, 1d
  • DIGITAL TRANSISTOR OUTPUTS
  • Quantity
  • 2
  • Type
  • Opto MOSFET
  • Maximum current
  • 90 mA
  • Maximum voltage
  • 48 Vc.c.
  • INTERNAL BATTERY
  • Capacity
  • 220 mAh
  • Type
  • Litio
  • Useful life
  • 10 años
  • Voltage
  • 3 Vc.c.
  • MEASUREMENT ACCURACY
  • Current asymmetry (Ka)
  • Class A (IEC 61000-4-30)
  • Voltage asymmetry (Ka)
  • Class A (IEC 61000-4-30)
  • Current unbalance (Kd)
  • Class A (IEC 61000-4-30)
  • Voltage unbalance (Kd)
  • Class A (IEC 61000-4-30)
  • Frequency measurement
  • Class 0,1 (45…65 Hz)
  • Phase current measurement
  • class 0,2 (1…200 % In) (IEC 61557-12)
  • Reactive energy measurement (kvarh)
  • Class 1 (IEC 62053-23)
  • Reactive power measurement (kvar)
  • Class 1 ± 1 digit (IEC 61557-12) (Vn ac 230/110)
  • Apparent power measurement (kVA)
  • class 0,5 ± 1 digit (IEC 61557-12) (Vn ac 230/110)
  • Active energy measurement (kWh)
  • Class 0,5S (IEC 62053-22)
  • Phase voltage measurement
  • Class 0.2 0,2 (10…1000 VF-N c.a.) (IEC 61557-12)
  • Flicker
  • 3 % (IEC 61000-4-15)
  • Pst Flicker
  • 5 % (0,2 … 10Pst) (IEC 61000-4-15)
  • Current harmonics (THD)
  • (up 50th) Class 1 (IEC 61000-4-7)
  • Voltage harmonics (THD)
  • (up 50th) Class 1 (IEC 61000-4-7)

 

Reviews

There are no reviews yet.

Be the first to review “MYeBOX-1500-3 FLEX-R80”