ODOT-PNM02 V2.1

Modbus (master/slave, RTU/ASCII) to ProfiNET, 2 port serial port (RS485/ RS232 / RS422), supports 50 slots, 200 commands in TIA portal (by configured software), support MAX 60 slaves

♦ Supports protocol conversion between Modbus and PROFINET

♦ Supports 2* RS485/RS232 or 1*RS422

♦ Supports Modbus master or slave, and supports RTU or ASCII

♦ Supports working temperature of -40〜85°C

♦ Supports data area: 2 serial Modbus-RTU/ASCII to PROFIBUS gateway with Max. input 1440 bytesand Max. output 1440 bytes

♦ Supports one key reset

♦ ODOT-PNM02 V2.0 supports Maximum slots: 50

♦ ODOT-PNM02 V2.1 supports 60 slaves (200 read and write commands)

 

Product Details

ODOT-PNM02 V2.0/V2.1 gateway is a Modbus-RTU/ASCII or non-standard protocol to ProfiNet protocol converter. It can realize the conversion from Modbus-RTU/ASCII or non-standard protocol to ProfiNet. Any device with RS485/RS232/RS422 interface supports Modbus-RTU/ASCII or non-standard protocol can use this product to realize interconnection with industrial bus ProfiNet. Such as: PLC, DCS, remote IO, VFD, scanner, motor start protection device, intelligent high and low voltage electrical appliances, electricity measuring device, intelligent field measuring equipment and instruments, etc.

 

ODOT-PNM02 V2.0 supports Maximum slots: 50

ODOT-PNM02 V2.1 supports 60 slaves (200 read and write commands)

 

The product marked as ODOT-PNM02 V2.0 and the GSD file uses the GSD configuration of PNM02L V2.0 in GSDMLV2.33-ODOT-PNM02-V2.0. The product marked as ODOT -PNM02 V2.1, and the GSD file uses the GSD configuration of PNM02L V2.1 in GSDMLV2.33-ODOT-PNM02-V2.0

The difference between PNM02V2.0 and PNM02V2.1 is that V2.0 can be directly uploaded GSD files to TIA Portal for configuration.

The detailed configuration parameters of V2.1 need to be configured with IO CONFIG, and overall parameters settings will be in TIA Portal.

It can select the gateway configuration mode in IO CONFIG

 

Technical Parameters

Mechanical Property

Shell: Aluminum alloy

Weight: 335g

Dimension: 27.5*110*80mm

Working Temperature: -40〜85°C

Storage Temperature: -55〜125°C

Relative Humidity: 5 〜95% (no condensation)

Input Voltage: 9〜36 VDC

Wiring: 3.81mm plug screw terminal

Power: Max. 200mA@24V

Modbus Serial

Port Number: 2

Serial Port: RS485/422/232

Wiring: 3.81mm plug screw terminal

ESD Protection: ±16KV

Rs485 Terminal Resistance: External 120Ω

Data Bits: 7,8

Stop Bits: 1,2

Checkdigit: None, even, odd

Baud Rate: 2400〜115200bps

Function Code: 01/02/03/04/05/06/15/16

Ethernet Interface

Protocol: PROFINET

ODOT-PNM02 V2.0 supports Maximum slots: 50

ODOT-PNM02 V2.1 supports 60 slaves (200 read and write commands)

Terminal Number: 2ways

Speed: 10/100Mbps self-adaption, Auto-MDI/MDIX

Connector: 8 Pin Rj45

Isolation Protection: Electromagnetic isolation

Main Technical Parameters

Installation: 35mm standard Din-rail

Supports Protocol: PROFINET I/O Device V2.3

PROFINET Data Area: Max. input of 1440 bytes & Max. output of 1440 bytes

ODOT-PNM02 V2.0 supports Maximum slots: 50

ODOT-PNM02 V2.1 supports 60 slaves (200 read and write commands)

Serial Isolation: Optical coupler isolation and power isolation

Serial Number: Supports 2*RS485/RS232 orl*RS422

Serial Terminal Resistance: need external resistance of 120Q

Serial Protocol: Supports Modbus-RTU/ASCII master, Modbus-RTU/ASCII slave

Serial Parameters: Supports baud rate of 1200~115200bps, supports none, even and odd digit check

Stations Supports Modbus 62pcs

Function Code Supports to Modbus 01/02/03/04/05/06/15/16

IPGrade: IP20

 

Others