RBX-80-400

Compare
Category:

Description

RBX-80-400

Code: P72155.

  • Reactor
  • L(mH): 0,47
  • For capacitor: 3 x CLZ-FP-46/33,3 | CFB-46/100
  • In (A): 120
  • Frequency (Hz): 50
  • kvar (400 V): 80
  • Losses (W): 246

 

INFORMATION

DESCRIPTION

CIRCUTOR has a standard range of rejection reactors p = 7%, with a resonance frequency of 189 Hz for 50 Hz networks (or 227 Hz on demand for 60 Hz networks). This is the most frequent tuning value to avoid any resonance of the 5th harmonic and higher. The capacitor-reactor assembly absorbs the portion of the current of the 5th order harmonic and acts as a detuned filter for higher frequencies. In some installations, other values of p% are required, for example 5.6% (210 Hz), 6% (204 Hz), 14% (134 Hz), etc. CIRCUTOR can build reactors on demand, which will be adapted to any power rating, p%, voltage and frequency. RX-type low-power reactors are built with low-loss plates and are coiled with a copper conductor. The connection is made using suitable terminals. In the case of higher power ratings, RBX reactors are used, with a magnetic plate nucleus with multiple air gaps, which offer excellent features and a very low loss ratio. Aluminium band coils are used (or copper band on demand) and the input and output connections run through a busbar. Both the RX and RBX reactors are impregnated with varnish in a vacuum to increase insulation, providing greater mechanical resistance and reducing noise levels.

APPLICATIONS

The rejection reactors of the RX / RBX series have been specifically designed for use in capacitor banks in installations with a high harmonic content. The reactors must be connected in series to each capacitor to ensure adequate protection of the capacitors and to prevent resonance effects in the installation.

SPECIFICATIONS

AC POWER SUPPLY

Frequency

50 Hz

ELECTRICAL CHARACTERISTIC

Overvoltage factor (p %)

7 % (189 Hz)

MECHANICAL CHARACTERISTICS

Size (mm) width x height x depth

305 x 235 x 155 (mm)

Envelope

Conductor type: Aluminium strip / copper cable

Weight (kg)

37

ENVIRONMENTAL CHARACTERISTICS

Thermal Class

class F (+155 ºC) On request: class H (+180 ºC)

Protection class

IP 00

Ambient temperature

-10 … +45 ºC

ELECTRICAL CHARACTERISTICS

Linearity (5% L)

1,8 x In

Maximum transient current

2 In (1 min)

Voltage

400 V,on request: up to 1000 V

Tolerance L

± 5 %

L value (mH)

0.47

Insulation voltage, circuit

4 kV

CURRENT MEASUREMENT CIRCUIT

Permanent overload

1,17 x In

STANDARDS

Standards

UNE-EN 60289, IEC 60076

PROTECTION

Circuit breaker type

90°C NC thermostat

 

Reviews

There are no reviews yet.

Be the first to review “RBX-80-400”

Your email address will not be published. Required fields are marked *